cTnI: Troponin I gwajin kit Fluorescence immunochromatography
Muhimmancin asibiti
Cardiac troponin I (cTnI) yana da ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙwayar cuta na zuciya, babban ji na rauni ga rauni na zuciya, da tsawon lokacin taga. Saboda kyakkyawar fahimta da ƙayyadaddun ƙayyadaddun sa, an yi amfani da shi azaman alamar da aka fi so don rauni na zuciya, wanda ke taimakawa ga farkon ganewar ƙwayar cuta mai tsanani da kuma tsinkayar tsinkayensa. Ɗaukaka troponin kuma yana ba da shaida mai ƙarfi don tallafawa yanke shawara na farko da likitocin asibiti suka yi akan maganin thrombotic, antiplatelet, da kuma maganin shiga tsakani.
Samfuradaki-daki
Amfanin samfur:
Babban hankali: ƙasa da ko daidai da 0.1 ng/mL
Faɗin layi mai faɗi: 1-60 ng/ml
Lokacin amsawa cikin sauri: 15 min
Lokacin ganowa da sauri: 7 s
Sigar aikin aiki:
Nau'in samfurin: jini, plasma da jini duka
Daidaitawa: CV ƙasa da ko daidai da 15%
Ƙimar magana: 0.3 ng/ml
Gwajin kwatance: Tare da ganowar Beckman Chemiluminescence cTnI daidaitawar R² ya kai 0.9788
Aikace-aikacen asibiti:
Myocardial infarction
Raunin kwarangwal
Rashin angina
Raunin zuciya

Aika sassan
Ya dace da sassan ilimin zuciya, sashen gaggawa, dakin gwaje-gwaje, likitan yara, tiyata, ciwon daji, sashin kulawa mai zurfi (ICU), ilimin jini, da sauransu.
FAQ
Tambaya: Menene fa'idodin nanophosphor na ƙasa da ba kasafai ba{0} tushen in vitro diagnostic reagents?
A: Cikakken ƙididdigewa: Yana ba da damar cikakken ƙididdigewa ga duk abubuwan rigakafi, haɓaka daidaiton ganowa.
Maɗaukakin Maɗaukaki: Uniformity da kyakkyawan tarwatsawa na nanophosphor microspheres na duniya da ba kasafai ba suna tabbatar da ingantaccen ganewa.
Ganewar gaggawa: Lokacin ganowa yana da sauri kamar daƙiƙa 10, tare da gabaɗayan tsari daga ɗaukar samfur zuwa fitarwar sakamako yana ɗaukar ƙasa da ko daidai da mintuna 15.
Ultra{0}}Mai hankali: Hannun samfur na iya kaiwa 10 pg/ml.
Faɗin Tsayin Rage: Yadda ya kamata yana rage tasirin ƙugiya kuma, haɗe tare da babban sigina -zuwa{1}}aramin ƙararrawar ƙara, yana faɗaɗa kewayon da ake iya ganowa sosai.
Rayuwar Shelf: Babu jigilar sarkar sanyi da ake buƙata, tare da dogon inganci (watanni 18).
Tambaya: Menene wannan kayan gwajin cTnI da ake amfani dashi?
A: An tsara wannan kit ɗin don ƙididdigewa ko rabin - ƙididdigar ƙididdigewa na Cardiac Troponin I (cTnI) a cikin samfuran jinin ɗan adam (kamar jini ko plasma). Yana da kayan aiki mai mahimmanci a cikin vitro diagnostic (IVD) don taimakawa wajen gano cutar ciwon zuciya na Myocardial (AMI), wanda aka fi sani da ciwon zuciya.
Tambaya: Ana buƙatar kayan aiki na musamman don karanta sakamakon?
A: Ee, ana buƙatar mai nazarin immunoassay na fluorescence don karanta sakamakon ƙididdiga. Muna ba da tashoshi guda ɗaya{1} da masu nazarin tashoshi 12 don siyarwa, masu dacewa da buƙatun kayan aikin dakin gwaje-gwaje daban-daban. Da fatan za a duba jerin samfuran mu don cikakkun bayanai.
Hot Tags: troponin i gwajin kit, China troponin i gwajin kit masana'antun, masu kaya